Introduction:
3720A and 3721A Electronic Loads provide an adaptable, and functional asset wherever power sources need to be tested.These units are designed to provide high reliability, great performance, and ease of operation with multiple functionality.


Features:
1 4 basic functions: CC, CV, CR, and CP ; and 8 basic test modes: CCL, CCH, CV, CRL, CRM, CRH, CPV, CPC
2 High-speedsequence, high-speed transient, short-circuit, battery discharge and other auxiliary functions
3 Minimum operating voltage is less than 0.6V at the load's full rated current
4 Optional zero-voltage test accessories are available
5 Programmable current slew rate
6 Perfect protection assures high reliability in the most complicated of test environments
7 Multiple groups of parameters and lists can be saved and recalled
8 Ruggedized structure, exquisite user-friendly design and convenient operation
9 Supports SCPI (Standard Commands for Programmable Instrumentation) and Labview, and provides necessary PC software

High Reliability

  • Protective circuitry provides over-current, over-voltage, over-power, over-temperature and reverse polarity protection to ensure the protection of the electronic load;
  • A high-speed, power limiting circuit can limit input power rapidly when it is overloaded, thus there is no need to interrupt testing. Equipment adaptability to complicated operational environments is thereby greatly enhanced.

Great Performance

  • Circuit improvement greatly enhances the dynamic response of CR mode and widens the application scope of that mode;
  • Minimum operating voltage is less than 0.6V at the load's full rated current. With optional low-voltage testing devices, the maximum current can be achieved even though the input voltage is 0V. This is especially suitable for fuel cell, solar cell and other new energy test applications;
  • By adopting an optimum design of calculation method and high-speed hardware circuitry, the D/A conversion rate can reach 100kHz. The overall smoothness of slope control has been raised, meanwhile, the timing precision and resolution of dynamic test and sequential test have also been improved;
  • The 24 bit A/D and 17 bit D/A converters incorporated, provide this equipment with greatly enhanced setting and measurement resolution.

Multifunction

  • Equipped with four basic test functions: CC, CV,CR, CP;
  • High-speed transient operation with separate high/low lever time and rising/falling time control;
       

  • Powerful sequential test function; with a minimum step time of 10us; and a maximum step time of 10000s. Cyclic numbers can be adjusted freely and a sequence can be chained to another sequence to achieve even more complex test procedures;
  • Providingshort-circuit test, battery discharge test and other auxiliary functions;
  • Remote input terminal and external trigger input terminals are provided. The remote measurement can monitor the input signal automatically, and it is not necessary to change wiring or modify settings during operation;
  • 10 groups of setup parameters can be saved, and providing automatic uploading of preset parameters;
  • By supporting SCPI, it is easy to build an ATE (automatic test equipment) system that works with other programmable instruments via optional RS232, USB and GPIB interfaces.

Easy Operation

  • Design optimized for portability and rugged reliability;
  • Logical keypad design and convenient test operation;
  • Easy-to-set test parameters coupled with a powerful sequence editing function;
  • All electronic calibration - therefore no need to dismantle the equipment-chassis;
  • Firmware can be updated online.

Specifications

(The warm-up time is 30 minutes. Specifications indicate warranted performance in the 25°C ± 5°C region of the total temperature range).


Model

3720A

3721A

Input Ratings
Current 0-30A 0-40A
Volatge 0-80V 0-80V
Power 250W @ 40 deg 400W @ 40 deg


Input Characteristics
Input Characteristics
3720A
3720A




*1. Maximum continuous power available is derated linearly from 100% of maximum at 40 degree, to 75% of maximum at 55 degree.

*2. Conductance (S) = 1 / Resistance (Ω)..

*3. The set level is 10 times larger than the slew rate in CCL mode.

*4. The actual transition time is defined as the time required for the input to change from 10% to 90% or from 90% to 10% of the programmed excursion.

*5. Transient frequency depends on the time for high/low level and rising/falling edge.

*6. Full remote control via RS232 with optional GPIB and USB.

Features

OPTION & ACCESSORY GPIB, USB
POWER ( Max.Input) 400 W
MODE PROGRAMMABLE
CURRENT 40 A
VOLTAGE 80 V
TYPE Bench Top
FUNCTION Electronic Load (DC)
CHANNELS 1CH
BRAND ARRAY
WEIGHT (Packed) 6.2 kg
SKU 71-0010
Manufactures Array

Reviews

Data Sheet

Download ARRAY 37XX DATA )
ARRAY 3271A Data Sheet

Datasheet

ARRAY 3271A User Manual 

Datasheet

© Racomtech Pty Ltd (ACN:134853 473) / EYou Trust Australia ( ABN 51 687 385 403)


  • +61-3-88029296
  • Sun 09:00—16:59
Dear friends!

Unfortunately, your browser does not support modern technology used on our website.

Please refresh your browser by downloading it on the links below or contact your system administrator serving your computer.

Internet Explorer

от Microsoft

Chrome

от Google

Safari

от Apple

Opera

от Opera Software

Firefox

от Mozilla